Show simple item record

Advancing accelerometry-based physical activity monitors: quantifying measurement errors and improving energy expenditure prediction

dc.creatorRothney, Megan Pearl
dc.date.accessioned2020-08-22T00:04:54Z
dc.date.available2008-04-10
dc.date.issued2007-04-10
dc.identifier.urihttps://etd.library.vanderbilt.edu/etd-03272007-072536
dc.identifier.urihttp://hdl.handle.net/1803/11485
dc.description.abstractAs the rate of obesity increases in the western world, the interest in understanding the process of maintaining healthy body weight has become an increasingly important public health priority. Because physical activity is the most variable component of energy expenditure both intra- and inter-individual, it has become a key factor in both individual weight loss prescriptions and public health recommendations. In spite of its widely recognized importance, the ability to accurately quantify patterns of physical activity has been limited by measurement technology that is often unable to render accurate predictions of energy expenditure over the course of days or weeks. One popular measurement tool for quantifying physical activity intensity is the accelerometer. Though the physical basis of the measurement would suggest that accelerometers can predict energy expenditure with a high degree of accuracy, to date, this promise has not been realized. This thesis addresses several critical gaps in our understanding of energy expenditure predictions using accelerometers. Three commercially available, single site accelerometers were coupled with seven regression equations from the literature to predict energy expenditure in a heterogeneous sample of healthy adult volunteers. We explored errors in energy expenditure prediction by both examining the accelerometer hardware as well as by proposing an analytical approach to energy expenditure prediction incorporating high frequency (32 Hz) data collection and artificial neural network modeling. Results of these experiments highlighted limitations in the single site accelerometers both in clinical data and in data collected using mechanically generated accelerations. Additionally we demonstrated improvements in energy expenditure prediction relative to single site accelerometers as well as a multi-site accelerometer array by using an artificial neural network approach for predicting energy expenditure. Results from these studies will be used to better understand the capabilities of accelerometers to assess physical activity in the field environment, which serves to improve our understanding of energy balance and obesity.
dc.format.mimetypeapplication/pdf
dc.subjectActical
dc.subjectActiGraph
dc.subjectANN
dc.subjectaccelerometer calibration
dc.subjectRT3
dc.subjectIDEEA
dc.subjectEnergy metabolism -- Measurement
dc.titleAdvancing accelerometry-based physical activity monitors: quantifying measurement errors and improving energy expenditure prediction
dc.typedissertation
dc.contributor.committeeMemberFrank Harrell
dc.contributor.committeeMemberPaul Harris
dc.contributor.committeeMemberRichard Shiavi
dc.contributor.committeeMemberCharles Matthews
dc.type.materialtext
thesis.degree.namePHD
thesis.degree.leveldissertation
thesis.degree.disciplineBiomedical Engineering
thesis.degree.grantorVanderbilt University
local.embargo.terms2008-04-10
local.embargo.lift2008-04-10
dc.contributor.committeeChairKong Chen
dc.contributor.committeeChairRobert Roselli


Files in this item

Icon

This item appears in the following Collection(s)

Show simple item record